Home CodeArduino Due Arduino Due and MLX90615 example

Arduino Due and MLX90615 example

by shedboy71

The MLX90615 is a miniature infrared thermometer for non-contact temperature measurements. Both the IR sensitive thermopile detector chip and the signal conditioning ASIC are integrated in the same miniature TO-46 can.

The infrared thermometer comes factory calibrated with a digital SMBus output giving full access to the measured temperature in the complete temperature range(s) with a resolution of 0.02 °C. The sensor achieves an accuracy of ±0.2°C within the relevant medical temperature range. The user can choose to configure the digital output to be PWM.

Features and benefits

Factory calibrated in wide temperature range: -20 to 85°C for sensor temperature and -40 to 115°C for object temperature
High accuracy of 0.5°C over wide temperature range (0..+50 C for both Ta and To)
Medical accuracy of 0.2°C in a limited temperature range
Measurement resolution of 0.02°C
SMBus compatible digital interface for fast temperature readings and building sensor networks
Customizable PWM output for continuous reading
3V supply voltage with power saving mode

 

Parts List

 

 

Amount Part Type
1 1PCS MLX90615 Digital Infrared Temperature Sensor for Arduino
1 Compatible DUE R3 Board SAM3X8E 32-bit ARM Cortex-M3

 

Layout

 

 

Code Example

This particular example comes from the following library which I installed – https://github.com/skiselev/MLX90615

I had issues with one of the other libraries – this one works just fine

[codesyntax lang=”cpp”]

#include <Wire.h>
#include <mlx90615.h>

MLX90615 mlx = MLX90615();

void setup()
{
Serial.begin(9600);
Serial.println(“Melexis MLX90615 infra-red temperature sensor test”);
mlx.begin();
Serial.print(“Sensor ID number = “);
Serial.println(mlx.get_id(), HEX);
}

void loop()
{
Serial.print(“Ambient = “);
Serial.print(mlx.get_ambient_temp());
Serial.print(” *C\tObject = “);
Serial.print(mlx.get_object_temp());
Serial.println(” *C”);
delay(500);
}

[/codesyntax]

 

Output

Open the serial monitor and you should see something like this. I moved a hot object near the sensor when the second value increased

 

 

Links

https://www.melexis.com/-/media/files/documents/datasheets/mlx90615-datasheet-melexis.pdf

Share

You may also like